Skip to main content
AI Studio  add-on for Spider.
cloudinary.net · HTTP 200

Cloudinary Scraper

Spider read cloudinary.net in 6.7 s without a browser and returned 162 lines of clean markdown, including sections like "Page 1", "Page 19" and "Page 20".

Get your free API key
Free balance on signup No card. Failed requests cost $0.
Response bel-cebeo.mo.cloudinary.net/PRODUCT/DOCUMENT/PictureServer/default.md markdown · 162 lines
D41L 18 Set-up and Maintenance/D isassembly and DisposalSet-up and MaintenanceFunctional testing The safety function of the safety components must be tested. The following conditions must be previously checked and met: 1.Check maximum. axial misalignment of actuator and safety door switch. 2.Check maximum. angular misal ignment. (Refer to Mounting.)3.Fitting and integrity of the cable connections. 4.Check the switch enclosure for damage. 5.Remove particles of dust and soiling. 6.For variants with an emergency exit, the following is to be considered: Note: 1. For variants with emergency ex its it should be possible to open the guard door inside the hazardous area; it should not be possible to lock the guard door from inside. MaintenanceMaintenance frequency SIL3 / PLe at least once a monthSIL2 / PLd at least once a year(Daily inspection)• For each guard door, check that the machine stops when the gua rd door opens. (Inspection every 6 months) • Check for a secure installation of the actuator and the safety door switch • Check maximum. axial misalignm ent of actuator and safety door switch. • Check maximum. angular misal ignment. (Refer to Mounting.) • Fitting and integrity o f the cable connections.• Check the switch enclosure for damages • Remove soiling Disassembly and DisposalDisassembly The product must be disassembl ed in a de-energized condition on ly. Disposal The product must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations.# Page 19D41L 19 Safety PrecautionsBe sure to read the precautions f or all models in the website at: http://www.ia.omron.com/. Warning IndicationsMeaning of Product Safety Symbols Alert Statements Use only appropriate components or devices complying with relevant safety standards corresponding to the required performance level and safety category. Failure to do so may result in serious injury or death. Conformity to requirements of the performance level and safety category must be determined as an entire system. It is recommended to consult a certification body regarding assessment of conformity to the required safety level. Do not apply DC voltages exceeding the rated voltages, nor any AC voltages to the product. Failure to do so may result in serious injury or death. Install the switch and actuator in a position where the opening of the guard door can be detected within a safe distance. Failure to do so may result in serious injury or death. Do not apply force exceeding the specified holding force (Fzh). Either insta ll another locking component (e.g., a hook) in addition to the product, or use a warning measures or an indicator showing the controlled system is locked to avid overloading the holding force in lock mode. Failure to do so may result in serious injury or death. When complying with safety standards, install the product in an appropriate manner in accordance with ISO 14119, with due consideration of the risk of defeat by the operator. Failure to do so may result in serious injury or death. Make sure that the DC power supply meets the following items. Failure to do so may result in serious injury or death. - Satisfies the requirements of PELV power supply defined in IEC 60204-1. - Satisfies the requirements of class 2 circuits defined in UL508.1.Disconnect the product from power supply when wiring the product. Failure to do so may cause unexpected operation of devices connected to the product. 2.Wire the input and output terminals correctly and verify the co rrect operation of the product before us ing the system in which the product is incorporated. Incorrec t wiring may lead to loss of t he safety function. 3.Install the actuator in a place where it will not come in conta ct with your body when opening or closing the guard door. Failure to do so may result in injury. 4.Do not use the product in any direction other than the specifie d mounting orientations of the main body and actuator. 5.Dispose of the product in accor dance with the laws set by each country.WARNINGIndicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, or undesirable effect on product performance. General prohibitionInstructions on unspecified prohibited action. General instructions Instructions on unspecified general action. WARNING Precautions for Safe Use# Page 20201.Do not drop the product to the ground or expose to excessive vibration or mechanical shocks. Doing so may damage the product and cause failure. 2.Do not store or use the produc t under the following conditions. Doing so may damage the product and cause failure. 1) At ambient operating temperatures out of the range of 0 to 6 0°C2) At ambient storage temperatures out of the range of -10 to 9 0°C3) At relative humidity of 93% or more 4) In direct sunlight 5) Under drastic temperature changes 6) In high humidity t hat causes condensation 3.Keep the product away from oil or solvent. Oil or solvent make the marking on the product illegible and cause deterioration of som e parts.4.Do not use in an environment with corrosive gas. 5.The product may not operate normall y in the vicinity of devices that generate strong radio waves or magnetic fields, such as RFID systems, proximity s ensors, motors, inverters, and switch-mode power supplies. If the device is used in the vicinity of such d evices, check the effect before use. 6.Installing the switch and the act uator on a metallic material m ay affect the operating distance. If installation on a metallic ma terial is necessary, be sure to check the effect on the operating dist ance before use. 7.Tighten the screws with a specified torque. 8.Use the wires specified by OMRON to wire the product. (Refer to Connection.) 9.Do not extend the cables in excess of the specification of this product. Carry out electrical c onnection according to the wirin g examples shown in this document and verify the correct operatio n of the product. 10.Do not pull or bend the cable ex cessively. A disconnection may cause a malfunction. 11. Risk time remains unchanged by series connection. However, carry out electrical connection according to the wiring example s shown in this document. 12.Be sure to inspect the product daily and every 6 months. Failur e to do so may cause a system failure and serious injury. 13.When determining the safety distance, take into account the del ay of the output of the product caused by the response time. Failu re to do so may cause the operator to reach the hazardous source before the machine is stopped, r esulting in serious injury. 14.During installation, make sure that the safety door switch does not come in contact with the actuator due to rattling of the guard door. (The performance of the product may be degraded by a collision caused by opening or closing the guard door.) 15.Install the product so that the LE D indicators of the safety do or switch are as visible as possibl e. Misinterpreting the status of the safety door switch may result in danger. 16.Do not use the product at an altitude of 2,000 m or higher. 17.Do not connect a product different from this product in series with this product. Doing so may disturb waveforms of the input and output signals, leading to los s of the safety function. 18.Do not use the product in the water or continuous water exposure environment. Doing so may cause w ater to leak into the product. (The degree of protection does not guarantee the protection und er continuous water exposure environment.) 19.Do not tamper the product with a replacement actuator. Store replacement actuators in a safe place where they cannot be easi ly reached.20.Build a safety system using the outputs of both Safety Outputs 1 and 2. Wiring with only one safety output may lead to loss of t he safety function due to a single failure. 21.Wiring should meet the requirement s specified in Section 9.4.3 of IEC 60204-1 to prevent malfunction due to ground faults in the safety output lines. 22.In the power-to-lock type, close the door before energizing the safety door switch. 23. In the power-to-lock type, the safety door switch is locked onl y when the solenoid is energized. If the solenoid is de-energized due to a sudden power failure, the operator may be exposed to a hazardous source. Use the power-to-lock type only for process protection. 24. Do not use the emergency-exit type for switching the machine on and off. Doing so may place operators at risk due to being trap ped inside or unexpected operation of the machine. 25. Install the emergency-exit type so that it cannot be operated from outside a safety zone. 26. Do not apply excessive force on the actuator while the actuator is inserted into the switch body or do not drop the product. Doing so may deform the actuator or damage the switch body. 27. The safety function may not operate normally due to a malfuncti on of the wiring, setting, or switch, and the machine may continue to operate, which may result in pe rsonal injury. Make sure that th e safety function works before starting operation. 28. The current consumption of the safety door switch is different between when it is turned on and when it is in a normal operati on. Apply the supply voltage to the safety door switch in considera tion of the voltage drop in the wiring. 29. Do not turn beyond the latching point. After being put into operation, the manual release must be secured by closing the fl ap cover with the seal, which is included in delivery. 30. After installation of the product, qualified personnel should v erify to see that the installation, inspection, and maintenance are properly performed. The qualifi ed personnel should be qualified and authorized to secure the safety on each phase of design, installation, running, maint enance and disposal of system. 31. Do not wire the product to an input of a safety controller in p arallel. 32. Disconnect the product and the controller connected to the prod uct from power supply when replaci ng the product. Failure to do so may cause unexpected operation of devices connected to the product. 33.Install the product to a position near a handle of the guard door. Installing it near a hinge may cause the locking part of the pr oduct to receive larger load than the operating force, leading to dam age to the locking mechanism. 34. Do not try to disassemble, repai r, or modify the product. Doing so may cause loss of the safety function. 35. Do not operate the product in an environment with flammable or explosive gas. 36. Auxiliary output is NOT a safety output. Do not use the Auxilia ry output individually for any safety function. Such incorrect use causes loss of the safety function of the product and its relevant systems. Precautions for Correct Use- Ecolab and its logo are registered trademarks of Ecolab USA In c.# Page 21
Code · Fields · Cost · Run it keyless, no account

The same call, in code.

The capture above came back as markdown. These examples add a key, so you get browser rendering, proxies, and concurrency on cloudinary.net.

cloudinary-net-scraper.ts
import { SpiderBrowser } from "spider-browser";

const spider = new SpiderBrowser({
  apiKey: process.env.SPIDER_API_KEY!,
});

await spider.connect();
const page = spider.page!;
await page.goto("https://cloudinary.net");

// No selectors, no schema. Spider reads the page and names the fields.
const data = await page.scrape();

console.log(data);
await spider.close();
ready to run · spider-browser, no selectors

Ready for volume? Get an API key →

Fields you can pull.

Product NamePricingFeaturesDescription

Spider names these from the page. The capture above came back as markdown; the same call with return_format: "json" returns them as keys.

What cloudinary.net costs to scrape.

The capture above cost $0.001917 to fetch. Pricing is $1 per GB of pre-transformation bandwidth plus $0.001 per CPU minute, so a page like this one lands at a fraction of a cent. Failed requests are billed at $0.

  • Free balance on signup
  • No card required to test
  • Balance never expires
See the full pricing →

Run it keyless, no account

curl -X POST https://api.spider.cloud/scrape -H "Content-Type: application/json" -d '{"url": "https://bel-cebeo.mo.cloudinary.net/PRODUCT/DOCUMENT/PictureServer/default.aspx?947FB0959B848C849988A89AA47C8390857A8475826D8C6B867D897B846E5EA4B4AB", "return_format": "markdown"}'

More SaaS scrapers.

Start scraping cloudinary.net.

You already have the call. A key raises the rate limit and turns on browser rendering, proxies, and concurrency. Balance never expires, and top-ups go through secure checkout.